Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Language
Document Type
Year range
1.
Integrated Communications, Navigation and Surveillance Conference, ICNS ; 2023-April, 2023.
Article in English | Scopus | ID: covidwho-20244358

ABSTRACT

The European Air Transportation Network was significantly impacted by the COVID-19 pandemic, resulting in an unprecedented loss of flight connections. Utilizing a combination of graph representation learning and time series analysis, this paper studies the evolution of both the global connectivity as well as the structure of the European Air Transportation Network from January 2020 to December 2022. Specifically, it finds strong differences in recovery rates for flights across six different market segments. In terms of network structure, the study finds that structural roles that are present in the pre-covid network have seen a loss in performance over the course of the pandemic, but have recovered to pre-covid levels. Using regional changes in structural roles, this study identifies Italy as the region with the strongest increase and the United Kingdom as the region with the strongest decrease in structural role, finding substantial differences in recovery rates per market segment. Lastly, this study pays special attention on the effect of the Russia-Ukrainian war on the European Air Transportation Network. © 2023 IEEE.

2.
J Hosp Infect ; 135: 74-80, 2023 May.
Article in English | MEDLINE | ID: covidwho-2285747

ABSTRACT

BACKGROUND: The global COVID-19 pandemic has resulted in a greater interest in improving the ventilation of indoor environments in order to remove aerosolized virus and thus reduce transmission. Air purification systems have been proposed as a solution to improve aerosol removal. AIM: The aim was to determine the efficacy of air purification systems in reducing the viral load in the environmental air of a room. METHODS: A containment room equipped with HEPA filter on air intake and exhaust was constructed. It was connected via an inlet with the BSL-2 facility. From the BSL-2, Feline Coronavirus (FCoV)-loaded aerosols were released into the containment room. After nebulization, air sampling was performed to determine the viral load in air prior to assessing the clean air delivery rate of the air purification systems. The infectivity of the captured viruses was also examined. FINDINGS: The air purification systems realized a 97-99% reduction in viral load in air in 1 h. Captured infectious FCoV was reduced by 99.9%-99.99% by use of an ESP technology. CONCLUSIONS: The air purification systems, using ESP technology or HEPA filter, reduce the viral load in air. The ESP purifiers inactivate captured FCoV viruses. Therefore, air purification systems can be used as an adjunctive infection control measure.


Subject(s)
Air Pollution, Indoor , COVID-19 , Animals , Cats , Humans , COVID-19/prevention & control , Air Pollution, Indoor/prevention & control , Pandemics , Respiratory Aerosols and Droplets , Infection Control
3.
J Hosp Infect ; 122: 168-172, 2022 Apr.
Article in English | MEDLINE | ID: covidwho-1729912

ABSTRACT

BACKGROUND: The global COVID-19 pandemic, accompanied by spikes in the number of patients in hospitals, required substantial amounts of respiratory protective devices (respirators), thereby causing shortages. Disinfection of used respirators by applying ultraviolet C (UVC) light may enable safe reuse, reducing shortages. AIM: To determine whether UVC disinfection is applicable to enable repeated safe reuse of respirators. METHODS: The UVC chamber, equipped with low-pressure mercury discharge lamps emitting at 254 nm, was used to determine the sporicidal and virucidal effects. Respirators challenged with spores and viruses were exposed to various UVC energy levels. Deactivation of the biological agents was studied as well as UVC effects on particle filtration properties and respirator fit. FINDINGS: A 5 log10 reduction of G. thermophilus spore viability by a UVC dose of 1.1 J/cm2 was observed. By simulating spores present in the middle of the respirators, a 5 log10 reduction was achieved at a UVC dose of 10 J/cm2. SARS-CoV-2 viruses were inactivated by 4 log10 upon exposure to 19.5 mJ/cm2 UVC. In case UVC must be transmitted through all layers of the respirators to reach the spores and virus, a reduction of >5 log10 was achieved using a UVC dose of 10 J/cm2. Exposure to a six-times higher UVC dose did not significantly affect the integrity of the fit nor aerosol filtering capacity of the respirator. CONCLUSION: UVC was shown to be a mild and effective way of respirator disinfection allowing for reuse of the UVC-treated respirators.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/prevention & control , Decontamination , Disinfection , Equipment Reuse , Geobacillus stearothermophilus , Humans , Pandemics , Spores, Bacterial , Ultraviolet Rays , Ventilators, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL